Skip to Content
Authors Richards AA, Afifi AM, Moneim MS
Author Profile(s)
Journal Tech Hand Up Extrem Surg Volume: 15 Issue: 2 Pages: 99-103
Publish Date 2011 Jun
PubMed ID 21606782
Abstract

Scapholunate advanced collapse and scaphoid nonunion advanced collapse wrist deformities are the most common causes of traumatic arthritis of the wrist. Four-corner fusion and scaphoid excision has proven to be an effective procedure for relieving pain and preserving range of motion in the wrist joint. Several methods for providing fixation of the midcarpal joint during fusion have been used, including K-wires, staples, and the Spider plate. K-wire fixation has proven effective, but requires a period of cast immobilization to protect the fusion mass. The Spider plate was promising, but has not been without complications. The development and improvements in cannulated headless compression screws has resulted in increased indications for their use, including fixation for 4-corner fusion. We review the technique and tips developed by the senior author over the last several years using headless compression screws for fixation of the midcarpal joint. Acutrak 2 Standard implants were used. This technique has allowed for early range of motion with reliable fusion rates.